Reducing valve for steam Yoshitake GD-30 DN20 JIS Rc CAC/SUS C/0.35-1.0MPa

Reducing valve for steam Yoshitake GD30 DN20 JIS Rc CACSUS C03510MPaReducing valve for steam Yoshitake GD30 DN20 JIS Rc CACSUS C03510MPaReducing valve for steam Yoshitake GD30 DN20 JIS Rc CACSUS C03510MPaReducing valve for steam Yoshitake GD30 DN20 JIS Rc CACSUS C03510MPa
in stock
delivery 7-24 days
Price: specify

Quantity

Total

specify

  • Manufacturer: Yoshitake (Japan)
  • Material: cast bronze, stainless steel, phosphor bronze
  • Action type: direct action
Quick order
Enter your phone number and
our manager will call you back
  • Description
  • Specifications
  • Dimensions (mm) and weight (kg)
  • Equipment selection schedule
  • Delivery, Payment
  • Slim design, compact and lightweight.
  • Simple construction, high strength and easy maintenance.
  • Easy installation thanks to threaded connection.
  • Possibility to adjust the pressure manually without any tools.
  • High wear resistance and strength of stainless steel valve and valve seat
  • A filter (60 mesh) is installed to protect the valve and seat from contamination.
  • Excellent performance provided by impulse tube external pressure bellows.
ModelGD-30
Nominal size15A-25A 40A • 50A
ApplySteam
Inlet pressureNo more than 1.7 MPa
Reduced pressure(A) 0.02-0.1 MPa (spring color: yellow)
(B) 0.05-0.4 MPa (spring color: blue)
(С) 0.35-1.0 MPa (spring color: yellow-green)
Min. differential pressure0.05 MPa
Max. coefficient pressure reduction10:1
Max temperature210 °C
Valve seat leaksNo more than 0.1% of nominal flow
MaterialBodyCast Bronze
Valve, valve seatStainless steel
BelfonPhosphor bronze
ConnectionJIS Rc Thread
Nominal SizedLHH1Weight
15ARc 1/280191471.9
20ARc 3/485191471.9
25ARc 195191772.0
40ARc 1-1/21403077710.1
50ARc 21503077710.4

GD-30 Schematic

Nominal Sizes Selection Chart (For Steam) 

Reducing valve for steam Yoshitake GD-30

[Example] 

When selecting the nominal size of a pressure reducing valve whose inlet pressure (P1), reduced pressure (P2), and flow rate are 1.3 MPa, 0.6 MPa, and 200 kg/h, respectively, first find the intersection point of the inlet pressure of 1.3 MPa and the reduced pressure of 0.6 MPa. Trace down vertically from this intersection point to find the nominal size with a flow rate of 200 kg/h or over. In this case, the nominal size is 20A. Note) The nominal sizes selection chart is based on measured data. As you can see, there is no specific relationship between the pressure difference and the flow rate in the chart above, and it is, therefore, impossible to calculate a fixed Cv value.

 * Set the safety factor at 80 to 90%.

Delivery

  • Delivery by Poland with DHL courier service to the branch - free
  • Delivery by Poland with DHL courier service to the branch at the address ("from door to door") - free

Payment

  • Cashless payment with VAT: OPEKS Energysystems sp.z.o.o., TIN 5273030184, Santander Bank Polska S.A., SWIFT: WBKPPLPP, account number: 69 1090 1056 0000 0001 5227 8036, IBAN: PL69 1090 1056 0000 0001 5227 80
  • Online Przelewy24 (Visa/MasterCard)
Reducing valve for steam Yoshitake GD30 DN20 JIS Rc CACSUS C03510MPa
Sorting
ApplyReset
Close
loading
loading